Error 0x800706F7 "The stub received bad data" on Windows XP SP3

In my VB6 application I make several calls to a COM server my team created from a Ada project (using GNATCOM). There are basically 2 methods available on the COM server. Their prototypes in VB are:

Sub PutParam(Param As Parameter_Type, Value)
Function GetParam(Param As Parameter_Type)

where Parameter_Type is an enumerated type which distinguishes the many parameters I can put to/get from the COM server and 'Value' is a Variant type variable. PutParam() receives a variant and GetParam() returns a variant. (I don't really know why in the VB6 Object Browser there's no reference to the Variant type on the COM server interface...).

The product of this project has been used continuously this way for years without any problems in this interface on computers with Windows XP with SP2. On computers with WinXP SP3 we get the error 0x800706F7 "The stub received bad data" when trying to put parameters with the 'Long' type.

Does anybody have any clue on what could be causing this? The COM server is still being built in a system with SP2. Should make any difference building it on a system with SP3? (like when we build for X64 in X64 systems).

One of the calls that are causing the problem is the following (changed some var names):

Dim StructData As StructData_Type

StructData.FirstLong = 1234567
StructData.SecondLong = 8901234
StructData.Status = True

ComServer.PutParam(StructDataParamType, StructData)

Where the definition of StructData_Type is:

Type StructData_Type
    FirstLong As Long
    SecondLong As Long
    Status As Boolean
End Type

(the following has been added after the question was first posted)

The definition of the primitive calls on the interface of the COM server in IDL are presented below:

// Service to receive data
HRESULT PutParam([in] Parameter_Type Param, [in] VARIANT *Value);

//Service to send requested data
HRESULT GetParam([in] Parameter_Type Param, [out, retval] VARIANT *Value);

The definition of the structure I'm trying to pass is:

struct StructData_Type
{
   int FirstLong;
   int SecondLong;
   VARIANT_BOOL Status;
} StructData_Type;

I found it strange that this definition here is using 'int' as the type of FirstLong and SeconLong and when I check the VB6 object explorer they are typed 'Long'. Btw, when I do extract the IDL from the COM server (using a specific utility) those parameters are defined as Long.

Update:

I have tested the same code with a version of my COM server compiled for Windows 7 (different version of GNAT, same GNATCOM version) and it works! I don't really know what happened here. I'll keep trying to identify the problem on WinXP SP3 but It is good to know that it works on Win7. If you have a similar problem it may be good to try to migrate to Win7.

like image 267
Guarita Avatar asked Apr 04 '13 20:04

Guarita


1 Answers

I'll focus on explaining what the error means, there are too few hints in the question to provide a simple answer.

A "stub" is used in COM when you make calls across an execution boundary. It wasn't stated explicitly in the question but your Ada program is probably an EXE and implements an out-of-process COM server. Crossing the boundary between processes in Windows is difficult due to their strong isolation. This is done in Windows by RPC, Remote Procedure Call, a protocol for making calls across such boundaries, a network being the typical case.

To make an RPC call, the arguments of a function must be serialized into a network packet. COM doesn't know how to do this because it doesn't know enough about the actual arguments to a function, it needs the help of a proxy. A piece of code that does know what the argument types are. On the receiving end is a very similar piece of code that does the exact opposite of what the proxy does. It deserializes the arguments and makes the internal call. This is the stub.

One way this can fail is when the stub receives a network packet and it contains more or less data than required for the function argument values. Clearly it won't know what to do with that packet, there is no sensible way to turn that into a StructData_Type value, and it will fail with "The stub received bad data" error.

So the very first explanation for this error to consider is a DLL Hell problem. A mismatch between the proxy and the stub. If this app has been stable for a long time then this is not a happy explanation.

There's another aspect about your code snippet that is likely to induce this problem. Structures are very troublesome beasts in software, their members are aligned to their natural storage boundary and the alignment rules are subject to interpretation by the respective compilers. This can certainly be the case for the structure you quoted. It needs 10 bytes to store the fields, 4 + 4 + 2 and they align naturally. But the structure is actually 12 bytes long. Two bytes are padded at the end to ensure that the ints still align when the structure is stored in an array. It also makes COM's job very difficult, since COM hides implementation detail and structure alignment is a massive detail. It needs help to copy a structure, the job of the IRecordInfo interface. The stub will also fail when it cannot find an implementation of that interface.

I'll talk a bit about the proxy, stub and IRecordInfo. There are two basic ways a proxy/stub pair are generated. One way is by describing the interfaces in a language called IDL, Interface Description Language, and compile that with MIDL. That compiler is capable of auto-generating the proxy/stub code, since it knows the function argument types. You'll get a DLL that needs to be registered on both the client and the server. Your server might be using that, I don't know.

The second way is what VB6 uses, it takes advantage of a universal proxy that's built into Windows. Called FactoryBuffer, its CLSID is {00000320-0000-0000-C000-000000000046}. It works by using a type library. A type library is a machine readable description of the functions in a COM server, good enough for FactoryBuffer to figure out how to serialize the function arguments. This type library is also the one that provides the info that IRecordInfo needs to figure out how the members of a structure are aligned. I don't know how it is done on the server side, never heard of GNATCOM before.

So a strong explanation for this problem is that you are having a problem with the type library. Especially tricky in VB6 because you cannot directly control the guids that it uses. It likes to generate new ones when you make trivial changes, the only way to avoid it is by selecting the binary compatibility option. Which uses an old copy of the type library and tries to keep the new one as compatible as possible. If you don't have that option turned on then do expect trouble, especially for the guid of the structure. Kaboom if it changed and the other end is still using the old guid.

Just some hints on where to start looking. Do not assume it is a problem caused by SP3, this COM infrastructure hasn't changed for a very long time. But certainly expect this kind of problem due to a new operating system version being installed and having to re-register everything. SysInternals' ProcMon is a good utility to see the programs use the registry to find the proxy, stub and type library. And you'd certainly get help from a COM Spy kind of utility, albeit that they are very hard to find these days.

like image 78
Hans Passant Avatar answered Nov 06 '22 10:11

Hans Passant