I have a COM server (C++/STA (MFC based app)) and a COM client (C#/MTA). The COM server must live in an STA, since it's an MFC app (I have no choice in this matter). The client issues a call to the server, and the server issues a callback to the client. That's where the error happens (RPC_E_CANTCALLOUT_ININPUTSYNCCALL
). I'm guessing if the server had been an MTA, this problem would never have arised, but sadly, the documentation for MFC explicitly denies initializing the apartment as an MTA.
Any ideas on how to work around this problem?
I have been toying with the idea of letting the server object (the object I expose through the running object table) live in an apartment of its own (MTA). Would this be a good idea, or is there something simpler to try first?
UPDATE
The server object is just a thin interface point to certain functions within the application. Most of the time it just reads and writes to memory locations, but there are instances where it generates window messages to various windows within the application. The server object itself is not the entire application.
RPC_E_CANTCALLOUT_ININPUTSYNCCALL means that you attempted to make a marshalled COM call from within the handler for a windows message sent via SendMessage
. This is to help avoid certain deadlock situations. You have a number of options, which boil down to "avoid COM calls in a SendMessage handler":
PostMessage
to queue up a message to yourself, and in that posted message handler, invoke the COM callback. No matter how much I twist and turn, I cannot remove myself of the STA context within the app when I'm being called from the client. It doesn't matter if I host the server object in an MTA, I still have to obey the laws of COM. The STA is a really nasty "correctional facility" in this case. I'm doing hard time...
This has led me to a rather ugly path, but it works. Instead of using COM to communicate back to the client, I'm hand rolling my own communications path to the MTA that hosts the server object and the callback references. I'm basically creating my own marshalling code by setting up a call queue (STL container with parameters to send), which the MTA thread picks up and delivers to the client. The response is then returned to the code that's responding to the initial call. Synchronization is done using Win32 event objects.
Luckily, there aren't many callbacks I have to cover, and the nature of the mechanism is static, and will only be used for my own purposes (will not be run in a production environment).
Wheew... Sometimes I wonder what life would've been if I chose to become a carpenter instead.
If you love us? You can donate to us via Paypal or buy me a coffee so we can maintain and grow! Thank you!
Donate Us With