I have a freshly built 64-bit Windows Server 2008 R2 box that I have installed 64-bit Coldfusion 9 Standard on. I've upgraded and hotfixed it up to the most current version of CF. I also had 64-bit Oracle 11g (11.1.0.7.0) Client installed on the box. I've created a System DSN using the 64-bit ODBC Data Source Administrator in Windows and can successfully test the connection of the data source.
All of these installations went smoothly, however, when I went to add a datasource in the Coldfusion Administrator I receive the error:
Connection verification failed for data source: myDatabaseName
java.sql.SQLException: [Macromedia][SequeLink JDBC Driver][ODBC Socket]internal error: The specified DSN contains an architecture mismatch between the Driver and Application The root cause was that: java.sql.SQLException: [Macromedia][SequeLink JDBC Driver][ODBC Socket]internal error: The specified DSN contains an architecture mismatch between the Driver and Application
I am having a hard time understanding exactly where this architecture mismatch is coming from since the box is entirely 64-bit. I see while looking at all the processes that are running, some related CF processes are running in 32-bit (Verity related processes, SOLR and CFDotNetSVC). I am not sure if those could cause this issue but I am at a loss to explain were this mismatch would come from otherwise.
Anyone have any ideas?
Using Dan's advice I grabbed a JDBC Driver from Oracle here:
http://www.oracle.com/technetwork/database/enterprise-edition/jdbc-111060-084321.html
I then moved the JAR (ojdbc6.jar in my case) and added it to my Coldfusion Class Path.
Determining the correct settings for using the datasource to Coldfusion was slightly harder but here are the settings I ended up going with:
JDBC URL: jdbc:oracle:thin:@//dbsrv.mydomain.com:1521/myDB.world
Driver Class: oracle.jdbc.driver.OracleDriver
Driver Name: Oracle Thin Driver
Then the username and password for the DB.
Sure enough it worked like a charm.
Dan, I want to give you a check mark because you definitely put me in the right direction, but I can only mark one correct.
I believe you need to either step down to the 32-bit drivers, or use native JDBC drivers to connect to Oracle successfully. My suggestion would be to go the JDBC route, and connect directly through a native Oracle JDBC driver by using the "other" selection on the Datasource screen. You'll get better performance that way, and have more control over your connection via ColdFusion.
Connecting to Oracle information in ColdFusion Livedocs.
i found an alternate way to do this
install the ODBC drivers for 64bit and 32bit (in that order) on your win2008 64bit OS
thereafter create the DSNs on both the System32 folder and SysWow64 folder by running the odbc32ad32.exe
ensure your tnsnames are setup fine in the respective network/admin folder (if you use tnsnames to maintain your sids)
now on the CF admin you creaet a new ODBC source with aODBC Socket and name. the next page should show you a drop down of all DSNs that exists in the 64bit DSN setup. When you go and test it in CF, it will strangely use the config of the 32bit DSN setup for validationb
voila....your connections should work. No worries of those architectural failures etc
If you love us? You can donate to us via Paypal or buy me a coffee so we can maintain and grow! Thank you!
Donate Us With