I have a Python/Flask web application that I am deploying via Gunicorn in a docker image on Amazon ECS. Everything is going fine, and then suddenly, including the last successful request, I see this in the logs:
[2017-03-29 21:49:42 +0000] [14] [DEBUG] GET /heatmap_column/e4c53623-2758-4863-af06-91bd002e0107/ADA
[2017-03-29 21:49:43 +0000] [1] [INFO] Handling signal: term
[2017-03-29 21:49:43 +0000] [14] [INFO] Worker exiting (pid: 14)
[2017-03-29 21:49:43 +0000] [8] [INFO] Worker exiting (pid: 8)
[2017-03-29 21:49:43 +0000] [12] [INFO] Worker exiting (pid: 12)
[2017-03-29 21:49:43 +0000] [10] [INFO] Worker exiting (pid: 10)
...
[2017-03-29 21:49:43 +0000] [1] [INFO] Shutting down: Master
And the processes die off and the program exits. ECS then restarts the service, and the docker image is run again, but in the meanwhile the service is interrupted.
What would be causing my program to get a TERM signal? I can't find any references to this happening on the web. Note that this only happens in Docker on ECS, not locally.
It turned out that after adding a login page to the system, the health check was getting a 302 redirect to /login at /, which was failing the health check. So the container was periodically killed. Amazon support is awesome!
If you love us? You can donate to us via Paypal or buy me a coffee so we can maintain and grow! Thank you!